Home Page Corporate Products Plazas Licensed Dealers Authorized Services Baykan News Communication
 Baykan Quality and service Conseption,



Baykan "star-plus" Wall Hung Boiler - Technical Information


 

 
24-28 kW Open Chamber
24-28-32 kW Sealed Closed Chamber
 

34/14.01/7623
TS EN 625 - TS EN 483
0694


Star-plus model  - 
Home Page
General features - 
Details   

Other Appliances

MAIN PARTS

 

1. Air pressure switch
2. Safety thermostat
3. Main exchanger
4. Combustion chamber 
5. Combustion chamber cover 
6. Motorized 3 way valve 
7. Central heating NTC sensor 
8. Safety valve
9. Domestic hot water NTC sensor 
10. Domestic hot water flow switch 

11. Pressure safety switch
12. Circulation pump
13. Gas valve 
14. Expansion vessel 
15. Burner
16. Ground electrode
17. Ignition electrode 
18. Fan
19. Flue gas safety thermostat 
20. Flue gas cell
21. Secondary heat exchanger


Baykan "star-plus"
Wall Hung Boiler
Technical Values

Open
Chamber
20.000 Kcal/h
Open
Chamber
24.000 Kcal/h
Sealed Closed Chamber
20.000 Kcal/h
Sealed Closed Chamber
24.000 Kcal/h

 24 OC

28 OC 24 SC 28 SC
GENERAL
Class   112H3+3B/P
PIN   ----
NOx type   3
Type   B11Bs C12-C32-C42-C52-C62
Type of gas   Natural Gas (G20)  -  LPG (G30 / G31)
Max heat input kW 26.5 31.0 26.5 31.0
Min heat input kW 9.0 10.0  9.0 10.0
Max heat output kW 24.1  29.0 24.9 29.0
Min heat output kW 7.5  8.4 7.6 8.4
Max efficiency % 91.0  91.0 94.2 93.7
Efficiency at 30% capacity % 89.0  89.0 91.7 91.5
Fume temperature (G20 20mbar) ºC 105  105 127 134
CENTRAL HEATING CIRCUIT 
Heating circuit water temperature min/max ºC 40 - 85
Expansion tank capacity lt 7.0
Expansion tank pressure bar 1.0
Heating circuit working pressure bar 3.0
Max heating circuit water temperature ºC 90
DOMESTIC HOT WATER CIRCUIT
Domestic hot water production (t= 25 ºC) lt/min 13.8  16.2 14.2 16.6
Domestic hot water production (t= 30 ºC) lt/min 11.5  13.3 12.0 13.8
Max pressure on DHW system bar 6.0
Min pressure on DHW system bar 0.8
Domestic hot water temperature Min/max ºC 30 / 60
ELECTRICAL CIRCUIT
Power supply voltage / frequency V / Hz 230 (±15 V) / 50
Electrical power W 104 104 152 152
Grade of protection IP x4D
DIMENSIONS
Width mm 400
Height mm 700
Depth mm 330
Weight Kg 38 40  40 41
CH circuit inlet/outlet in 3/4 "
DHW inlet/outlet in 1/2 "
Gas circuit in 3/4 "
Flue pipe diameter mm 130 140 60 / 100
Flue pipe length min/max m --- ---  0.5 - 5.0
Parallel flue pipe / pipe inlet dimension mm --- ---  80 / 80
GAS NOOZLE PRESSURES
Natural gas (G20) max mbar 11.5 13.1  11.5 13.1
Natural gas (G20) min mbar 1.4  1.4 1.4 1.4
LPG (G30 / G31) max mbar 27.5 / 35.3  27.4 / 35.2 27.5 / 35.3 27.4 / 35.2
LPG (G30 / G31) min mbar 3.8 / 4.6  3.0 / 3.8 3.8 / 4.6 3.0 / 3.8
Ø Natural gas noozle dimension mm 1.30  1.30 1.30 1.30
Ø LPG noozle dimension  mm 0.77  0.78  0.77 0.78  
GAS CIRCUIT
Natural gas (G20) mbar 20
LPG (G30/G31) mbar 29 / 37
Natural gas consumption  m3/h 2.74  3.2 2.74 3.2

 

 