  • Small dimensions and light weight
  • Microprocessor controlled board
  • Antifreezing protection system
  • Accurate temperature adjustment on central heating circuits ± 1 °C
  • Timer room thermostat connection
  • Electrical three way valve
  • Pump feature that does not allow the pump run without water
  • Automatic by-pass system
  • Overheat sensor
  • Secondary water exchanger 
  • Electronic ignition
  • Ignition control with ionization electrode
  • Pump anti-blockage system
  • Easily adjustable circulation pump
  • Low NOx level
  • Electronic full modulation
  • Ergonomic and LED controlling board
  • Operability with natural gas and LPG
  • Lower gas consumption, higher efficiency
  • Anti-calc system against calcifying
  • Sensor to prevent overheating :   This is the safety system that provides stopping the burning operation of the Hung-wall boiler, in case the temperature of the circuit water is more than 100°C (and the other system sensors cannot fulfill their duty). In this way, this system provides damaging the hung wall boiler.
     
  • Control of the Fire with Ion Electrode: In case the burner is going out, the ion electrode, that is permanently in contact with flame upon the burner, is sending this situation to the electronic card and is turning off the gas. In this way, is prevented the gas consumption and gas leakage
     
  • The Automatic By-Pass System: Our Wall-Hung Boilers are provided with a by-pass pipe wich is allowing the water to pass only into one way between all way crane and return group. In this way, even if all the cranes of the wall-hung boiler are closed, it provides the water circulation of 350 lt/h and prevents damaging of the boiler.
     
  • Anti-Pump Seizing System preventing the pump working without water: This is the safety system stopping the boiler working and preventing Due to the pressure sensor that is situated on the circulation pump of the wall-hung boiler, in case the water pressure on the circuit is under 0,6 bar.
     
  • Anti-Frost System against Freezing : During cold weather, in case the water from the inner circuit of the boiler decreases under 5°C the burner starts burning and is heating the water till 36°C. In this way the system prevents cracking of the circulation pump, heat exchanger and other pieces of the boiler due to the freezing events.
     
  • Anti-Block System Preventing the Jamming of the Pump : This is the system providing the functioning of the pump for 20 seconds, once every 21 hours, in order to prevent the jamming of the pump, in case the boiler is not used for a long period.
     
  • A Special Filter on the Entrance of the Cold Water : Due to the filter positioned after the ball valve allowing the boiler to receive water, it provides the possibility to clean the water from foreign substances.
     
  • Anti-Calc System against Calcifying : The heating of the central heating water is achieved by a separate steel plate exchanger. In case the central heating water going through plate exchanger is over a warm degree, the is capturing calc. Due to the warmth sensor positioned here, it provides the heating of the water at the expected degree, meanwhile is preventing the calcifying of the water. 
  • Safety Valve : In case the pressure of the water is exceeding over 3 bar, this valve is providing the evacuation of the water surplus from the system by using this valve in order to prevent the damage of the boiler.
     
  • The Gradual Circulation Pump : This is a system providing the adjustment of According to the client/user demand.
     
  • Elektronic Full Modulation : Due to a special programme electronical card situaated on the boiler, all the operations regarding the values are provided by an delectronic card.
     
  • Electronic Ignition: Using only one button it provides electronic ignition and the functioning of the boiler.
     
  • The Values of hot water indicated by led index : Situated on the front panell of the boiler this is the system informing the user about the water temperature.
     
  • A Sensible Setting of the Water of Central System and of Heating : Due to the sensors, different for hot water and heating system of the boiler a temperature setting of ±1°C can be done providing also savings of gas and a better confort.
     
  • Isolation Protection : Our wall hang boiler are produced from inox sheet iron using the best tehnology of moulding. The burning room is very well isolated, having also an extra second isolation. Due to this second isolation it achieves a 5 % savings and isolation against noise, providing a better functioning and more confort. This isolation system is realised from one piece only, being a high quality system in Europe.
starplus front panel
A. Domestic water temperature adjustment button
B. Off-Reset button and summer/winter adjustment
C. Central heating circuit temperature adjustment button
D. Manometer (Pressure gauge)
E. Power gauge
F. Flame indicator
G. Displays the temperature of heating system or break downs as is flashes
Product Catalogues
Operation Manuals
Baykan Kombi Ücretsiz Keşif Talep Formu


Room Thermostat (OPTIONAL)
• Stabilizes the room temperature
• Ensures energy saving till 20%   